The KN model is a secondary pressure regulator that offers maximum sensitivity and ensures simple, trouble-free operation. It is suitable for low-pressure applications using natural gas and liquefied petroleum gas fuels. This regulator is primarily intended for equipment with a rated power of up to 30 kW (40 hp). Units with higher flow capacities are equipped with a ½-inch port and are designed for applications up to 37 kW (50 hp). The KN‑model regulator can be reassembled using IMPCO’s service kits.
  • Product Description
  •   MODEL KN Pressure Regulator

      Explanation

      The KN model is a secondary pressure regulator that offers maximum sensitivity and ensures simple, trouble-free operation. It is suitable for low-pressure applications using natural gas and liquefied petroleum gas fuels. This regulator is primarily intended for equipment with a rated power of up to 30 kW (40 hp). Units with higher flow capacities are equipped with a ½-inch port, making them appropriate for applications up to 37 kW (50 hp). The KN‑model regulator can be reassembled using IMPCO’s service kits.

      Specifications

      Fuel Type .......................... Liquefied Petroleum Gas or Natural Gas

      Inlet pressure

      Maximum value.................................13.84” w.c. (3.44 kPa)

      Rated outlet pressure ..............-0.12 kPa (-0.5” or below w.c.)

      Power

      Liquefied petroleum gas (standard)...........................40 hp (30 kW)

      Liquefied petroleum gas (high flow)...........................50 hp (37 kW)

      Natural gas (standard).....................25 hp (19 kW)

      Natural gas (high flow)....................30 hp (22 kW)

      Operating temperature range...................-40°F to +250°F (-40°C to +121°C)

      Filtration accuracy requirement: 40 microns

      Installation Position ......................................... Vertical installation is recommended (with the outlet facing downward). If the specified liquefied petroleum gas fuel for HD-5 or HD-10 is clean and free of excessive contaminants, horizontal installation is also permissible.

      Diaphragm material......................................silicone rubber

      Application...................................................Base-type

      Certification...................................UL (AU1502) ECE for special certification

      A Overall height B Overall width C Overall depth D Fuel inlet (NPT) E Fuel outlet (NPT) F Mounting hole spacing G Mounting hole spacing H Maximum inlet pressure I Recommended inlet pressure J Start-up accelerator